PVB IBP Transducer PB Single Type Disposable Transducer Invasive Blood Pressure

PVB IBP Transducer PB Single Type Disposable Transducer Invasive Blood Pressure

Product Details:

Place of Origin: China
Brand Name: PVB (PB)
Certification: CE & ISO 13485
Model Number: BIY-PB-01

Payment & Shipping Terms:

Minimum Order Quantity: 10pcs
Price: depends on quantity & negotiation
Payment Terms: Western Union, MoneyGram, L/C, T/T
Get Best Price Contact Now

Detail Information

Product Name: PVB PB Single Type Disposable IBP Transducer Connector: PVB Connector
Patient Size: Adult/Pediatric/Neonate Warranty: 0 Month
Compatibility: Universal OEM: Availible
Highlight:

PVB ibp transducer

,

neonate transducer invasive blood pressure

,

disposable transducer invasive blood pressure

Product Description

Disposable IBP transducers typically consist of a small, flexible catheter that is inserted into an artery, and a transducer that is attached to the end of the catheter. The transducer converts the pressure inside the artery into an electrical signal, which is then transmitted to a monitor that displays the patient's blood pressure in real time.

 

1. Product Name

PVB PB Single Type Disposable IBP Transducer

 

2. Technical Parameters

Main technical parameters and working environment requirements:

Disposable Pressure Transducer

Barometric pressure

70~106Kpa

Relative humidity

10~90% (non-condensing)

Operating pressure range

-50 ~ + 300 mmHg

Sensitivity

5.0μV/V/mmHg ±3%

Nonlinearity and hysteresis

full-scale reading±1.5%

Input impedance

1200Ω ~3200Ω

Zero pressure offset

-20mmHg~+20mmHg

Thermal offset shift

≤±0.3mmHg/°C

Offset drift

After warm-up for 20 seconds, drift within 2 mmHg within 8 hours

Thermal span shift

≤±0.1%/°C

Frequency response

Standard pressure set (48 "/ 12") is 40 Hz; Separate sensor > 200 Hz

Defibrillator withstand

Defibrillation depends on the final connection of the equipment.

Leakage current

Leakage current is dependent on the final connection of the equipment

Overpressure load

-400~+4000mmHg

Shock resistance

Withstand falling from one meter for three times

 

Light sensitivity

When exposed to a 3400°K tungsten light, candle light at 3000 feet, it's less than 1 mmHg under rated voltage.

Storage and transport environment requirements

- 20 ° C~ + 60 ° C, < 90%(non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold.

Contact with the human body

≤168h

Intra-system velocity

Flow

2-5mL/h

Intra-system refers to the velocity under 6.00 VDC and 25°C, unless there are additional instructions.

 

3. Other Models :

REF

Sensor Desription

BIY-PB-01

Single Type PVB(PB) Connector

BIY-PB-02

Dual Type PVB(PB) Connector

BIY-PB-03

Ternary Type PVB(PB) Connector

 

4.  Certificates

PVB IBP Transducer PB Single Type Disposable Transducer Invasive Blood Pressure 0

 

5. Delivery details:
1) Our production cycle:
Item will be shipped within 4-7 working days after we get your Payment, We are always serious on the delivery time, all orders will be checked by us carefully to make sure there is no delay on the shipment.

2) Shipping Methods:
a).we usually send goods by DHL,Fedex,TNT,UPS, Tracking number will be advised after delivery, all of express lead time is about 5-7 working days.
b). If order is big, we will suggest you use Air Freight or Sea freight.


6. About Sample
1) if we have the product you need , we can send you the sample free
2) if we have not the product you need, we advice you send us one piece of sample,
We will check how to produce it for you .

 

 

Want to Know more details about this product
I am interested in PVB IBP Transducer PB Single Type Disposable Transducer Invasive Blood Pressure could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.