Ternary Type Disposable IBP Transducer Blood Pressure P-Hilips For IBP Adapter Cable
Product Details:
Place of Origin: | China |
Brand Name: | Philips |
Certification: | CE & ISO 13485 |
Model Number: | BIY-BB-03 |
Payment & Shipping Terms:
Minimum Order Quantity: | 10pcs |
---|---|
Price: | depends on quantity & negotiation |
Payment Terms: | Western Union, MoneyGram, L/C, T/T |
Detail Information |
|||
Properties: | Medical Materials & Accessories | Type: | Ternary Type |
---|---|---|---|
Connector: | Philips BB B. Braun Connector | Patient Size: | Adult/Pediatric/Neonate |
Key Words: | Patient Monitor Cable, Invasive Blood Pressure Cable | OEM Number: | 989803194631 |
High Light: | Ternary Type Blood Pressure Transducer,IBP Transducer for Adapter Cable |
Product Description
1. Product Name
P-hilips BB B. Braun Dual Double Type Disposable IBP Transducer Blood Pressure Transducer for IBP Adapter Cable
2. Description Of Disposable IBP Transducer
This is the gold standard of blood pressure measurement giving accurate beat-to-beat information. In general, systolic pressure will be slightly higher and diastolic pressure slightly lower (5¿¿10 mm Hg), than non-invasive measurements. It is useful when rapid changes in blood pressure are anticipated (due to cardiovascular instability, large fluid shifts or pharmacological effects) or when non-invasive blood pressure monitoring is not possible or likely to be inaccurate (obesity, arrhythmias such as atrial fibrillation, non-pulsatile blood flow during cardiopulmonary bypass). It is also used when long-term measurement in sick patients is required as it avoids the problem of repeated cuff inflation (causing localized tissue damage) and allows repetitive sampling for blood gases and laboratory analysis.
Continuous invasive BP monitors display the information both numerically and graphically. The basic principle is to provide a solid column of liquid connecting arterial blood to a pressure transducer (hydraulic coupling) and requires the following components:
(1) Intra-arterial cannula;
(2) Tubing (incorporating an infusion system)
(3) Transducer
(4) Microprocessor and display screen
(5) Mechanism for zeroing and calibration.
3. Technical Parameters
Main technical parameters and working environment requirements: |
||||
Disposable Pressure Transducer |
||||
Barometric pressure |
70~106Kpa |
|||
Relative humidity |
10~90% (non-condensing) |
|||
Operating pressure range |
-50 ~ + 300 mmHg |
|||
Sensitivity |
5.0μV/V/mmHg ±3% |
|||
Nonlinearity and hysteresis |
full-scale reading±1.5% |
|||
Input impedance |
1200Ω ~3200Ω |
|||
Zero pressure offset |
-20mmHg~+20mmHg |
|||
Thermal offset shift |
≤±0.3mmHg/°C |
|||
Offset drift |
After warm-up for 20 seconds, drift within 2 mmHg within 8 hours |
|||
Thermal span shift |
≤±0.1%/°C |
|||
Frequency response |
Standard pressure set (48 "/ 12") is 40 Hz; Separate sensor > 200 Hz |
|||
Defibrillator withstand |
Defibrillation depends on the final connection of the equipment. |
|||
Leakage current |
Leakage current is dependent on the final connection of the equipment |
|||
Overpressure load |
-400~+4000mmHg |
|||
Shock resistance |
Withstand falling from one meter for three times |
|||
Light sensitivity |
When exposed to a 3400°K tungsten light, candle light at 3000 feet, it's less than 1 mmHg under rated voltage. |
|||
Storage and transport environment requirements |
- 20 ° C~ + 60 ° C, < 90%(non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold. |
|||
Contact with the human body |
≤168h |
|||
Intra-system velocity |
||||
Flow |
2-5mL/h |
|||
Intra-system refers to the velocity under 6.00 VDC and 25°C, unless there are additional instructions. |
4. Other Models :
REF |
Sensor Desription |
BIY-BB-01 |
Single Type P-hilips BB Connector |
BIY-BB-02 |
Dual Type P-hilips BB Connector |
BIY-BB-03 |
Ternary Type P-hilips BB Connector |
5. Company Product :
Reusable SpO2 Sensor
Disposable SpO2 Sensor
SpO2 Adapter Cable
ECG Cable and Leadwires
EKG Cable and Leadwires
ECG Holter Cablel and Leadwires
ECG Trunck Cable 3/5/10 Lead
ECG Leadwires 3/5/10Lead
ECG Electrodes and ECG/EKG Accessories
Radiatranparent ECG Cable and Leadwires
Temperature Probe and Adapter Cable
IBP Cable and Adapter Cable and Disposable IBP Transducer
NIBP Cuff and NIBP Adapter Hose Tube
EEG Electrodes Leadwires
Spare parts and semi-sinished cables
6. Certificates
7. Delivery details:
1) Our production cycle:
Item will be shipped within 4-7 working days after we get your Payment, We are always serious on the delivery time, all orders will be checked by us carefully to make sure there is no delay on the shipment.
2) Shipping Methods:
a).we usually send goods by DHL,Fedex,TNT,UPS, Tracking number will be advised after delivery, all of express lead time is about 5-7 working days.
b). If order is big, we will suggest you use Air Freight or Sea freight.
8. About Sample
1) if we have the product you need , we can send you the sample free
2) if we have not the product you need, we advice you send us one piece of sample,
We will check how to produce it for you .
9. FAQ
Q: Are you trading company or manufacturer?
A: We are original manufacturer. We can do OEM/ODM business.
Q: What is your terms of payment and way of payment?
A: 100% payment in advance. Payment by TT/Western Union/Paypal/Alibaba/Ali pay/Wechat /L/C(some countries )are acceptable.
Q: How to buy your products?
A: You can buy the products from our company directly.Normally the procedure is sign the contract, make payment,Contact the courier to deliver goods .
Q:Can your provide customize or OEM service?
A: 1. We can add customer's logo on the product or package if samples or design is provided.
2. We can provide design service or manufacture if sample or design is provided.
Q: Can we become your distributor in local?
A: Yes ,We are looking for distributors in every country or region .If you are interested in distribution ,you can email us freely.